December 2005 © TOSHIBA TEC e-STUDIO163/203 ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 47
2
520 Fuser Fuser roller temperature
during printing
(Center thermistor/Enve-
lope)
ALL 9
<0-14>
M 0: 140°C 1: 145°C
2: 150°C 3: 155°C
4: 160°C 5: 165°C
6: 170°C 7: 175°C
8: 180°C 9: 185°C
10: 190°C
11: 195°C
12: 200°C
13: 205°C
14: 210°C
1
521 Fuser Fuser roller temperature
during printing
(Side thermistor/Envelope)
ALL 9
<0-14>
M 0: 140°C 1: 145°C
2: 150°C 3: 155°C
4: 160°C 5: 165°C
6: 170°C 7: 175°C
8: 180°C 9: 185°C
10: 190°C
11: 195°C
12: 200°C
13: 205°C
14: 210°C
1
523 Fuser Pre-running time for first
printing
(Envelope)
ALL 10
<0-15>
M 0: Invalid 1: 1 sec.
2: 2 sec. 3: 3 sec.
4: 4 sec. 5: 5 sec.
6: 6 sec. 7: 7 sec.
8: 8 sec. 9: 9 sec.
10: 10 sec.
11: 12 sec.
12: 14 sec.
13: 16 sec.
14: 18 sec.
15: 20 sec.
1
525-0 Fuser Temperature
drop switching
time setting
during printing
(Center ther-
mistor)
The first
drop
ALL 20
<0-200>
M This code is valid only
when “20” is set to 08-
535.
Setting value x 5 sec.:
from 0 to 1,000 sec.
later
4
525-1 The sec-
ond drop
ALL 38
<0-200>
M 4
525-2 The third
drop
ALL 75
<0-200>
M 4
525-3 The fourth
drop
ALL 75
<0-200>
M 4
526 Fuser Pre-running time for first
printing (OHP film)
ALL 0
<0-15>
M 0: Invalid 1: 0 sec.
2: 2 sec. 3: 3 sec.
4: 4 sec. 5: 5 sec.
6: 6 sec. 7: 7 sec.
8: 8 sec. 9: 9 sec.
10: 10 sec.
11: 12 sec.
12: 14 sec.
13: 16 sec.
14: 18 sec.
15: 20 sec.
1
527-0 Fuser Temperature
drop switching
time setting
during printing
(Side ther-
mistor)
The first
drop
ALL 20
<0-200>
M This code is valid only
when “20” is set to 08-
535.
Setting value x 5 sec.:
from 0 to 1,000 sec.
later
4
527-1 The sec-
ond drop
ALL 30
<0-200>
M 4
527-2 The third
drop
ALL 48
<0-200>
M 4
527-3 The fourth
drop
ALL 75
<0-200>
M 4
Setting mode (08)
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAM Contents
Proce-
dure