EasyManua.ls Logo

Toshiba e-STUDIO203 - Page 68

Toshiba e-STUDIO203
222 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
e-STUDIO163/203 ERROR CODE AND SELF-DIAGNOSTIC MODE December 2005 © TOSHIBA TEC
2 - 48
535-0 Fuser Temperature
drop control
setting during
printing
(Tempera-
ture/ Time)
Plain
paper
ALL 2
<0-20>
M 0: None
1: Pattern 1
2: Pattern 2
3: Pattern 3
4: Pattern 4
5: Pattern 5
6: Pattern 6
7: Pattern 7
8: Pattern 8
9: Pattern 9
10: Pattern 10
11: Pattern 11
12: Pattern 12
13: Pattern 13
14: Pattern 14
15: Pattern 15
16: Pattern 16
17: Pattern 17
18: Pattern 18
19: Pattern 19
20: Manual adjustment
4
535-1 Thick
paper
ALL 12
<0-20>
M 4
536-0 Fuser Temperature
drop setting
during printing
(Center ther-
mistor)
The first
drop
ALL 1
<0-10>
M This code is valid only
when “20” is set to 08-
535.
Setting value x -5°C:
from 0°C to -50°C
4
536-1 The sec-
ond drop
ALL 2
<0-10>
M 4
536-2 The third
drop
ALL 3
<0-10>
M 4
536-3 The fourth
drop
ALL 3
<0-10>
M 4
537-0 Fuser Temperature
drop setting
during printing
(Side ther-
mistor)
The first
drop
ALL 1
<0-10>
M 4
537-1 The sec-
ond drop
ALL 2
<0-10>
M 4
537-2 The third
drop
ALL 3
<0-10>
M 4
537-3 The fourth
drop
ALL 5
<0-10>
M 4
538 Image Density default in image
quality mode
ALL 0
<0-7>
SYS 0: AUTO 1: Light 3
2: Light 2 3: Light 1
4: Center 5: Dark 1
6: Dark 2 7: Dark 3
1
539-0 Fuser Temperature
drop setting
during printing
(Side ther-
mistor/ Thick
paper)
The first
drop
ALL 1
<0-10>
M This code is valid only
when “20” is set to 08-
535.
Setting value x -5ºC:
from 0ºC to -50ºC
4
539-1 The sec-
ond drop
ALL 2
<0-10>
M 4
539-2 The third
drop
ALL 3
<0-10>
M 4
539-3 The fourth
drop
ALL 3
<0-10>
M 4
Setting mode (08)
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAM Contents
Proce-
dure

Table of Contents