e-STUDIO163/203 ERROR CODE AND SELF-DIAGNOSTIC MODE December 2005 © TOSHIBA TEC
2 - 54
886 Fuser Temperature drop control
setting in ready status
(Temperature/Time)
ALL 4
<0-20>
M 0: None
1: Pattern 1
2: Pattern 2
3: Pattern 3
4: Pattern 4
5: Pattern 5
6: Pattern 6
7: Pattern 7
8: Pattern 8
9: Pattern 9
10: Pattern 10
11: Pattern 11
12: Pattern 12
13: Pattern 13
14: Pattern 14
15: Pattern 15
16: Pattern 16
17: Pattern 17
18: Pattern 18
19: Pattern 19
20: Manual adjustment
1
896-0 Fuser Temperature
control lower
limit
(Plain paper/
Low tempera-
ture)
Center
thermistor
ALL 7
<0-12>
M 0: 130°C 1: 135°C
2: 140°C 3: 145°C
4: 150°C 5: 155°C
6: 160°C 7: 165°C
8: 170°C 9: 175°C
10: 180°C
11: 185°C
12: 120°C
4
896-1 Side ther-
mistor
ALL 5
<0-12>
M 4
900 Version System firmware ROM ver-
sion
ALL - - T280SY0Wxxx
Displays only the “xxx”
part of the above code.
2
921 Version FROM internal program ALL - - VTRxx.xxxW
Displays the "xx.xxx"
part of the above code
as "xx-xxx". (Press the
reproduction ratio but-
tons to switch the dis-
play between "xx-"and
"xxx".)
2
949 General Automatic interruption
page setting during printing
ALL 0
<0-100>
SYS Sets the automatic
interruption page.
1
970 User
interface
Sound setting when
switching to Energy Saving
Mode
ALL JPN: 0
Other: 1
<0-1>
SYS 0: OFF
1: ON
1
Setting mode (08)
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAM Contents
Proce-
dure
06/07