e-STUDIO205L/255/305/355/455 © 2009 TOSHIBA TEC CORPORATION All rights reserved
ADJUSTMENT
3 - 56
Drawer feeding
(1) Remove 1 screw and the stopper. And then
take off the drawer.
Fig. 3-44
(2) Lift up the drawer paper tray. Take off the
drawer tray upward by releasing it from a
stopper on the front side.
Fig. 3-45
(3) Move 1 screw to a position for the
adjustment screw. (If it is already moved,
skip this step.)
Fig. 3-46
Stopper
Stopper
Drawer tray