EasyManua.ls Logo

Toshiba e-STUDIO2303A - Page 551

Toshiba e-STUDIO2303A
730 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
05/08 Mode Element Sub element Item Subitem Code
Sub-
code
Details
Default
value
Acceptable
value
SRAM Contents
Proce
dure
20L
/
23L/
25L
20H
/
23H/
25H
08 Setting
mode
Process Fuser 2090 - Printing temperature
drop control
1 0-6 M 0: Invalid
1: (Normal temperature / Low temperature) Plain paper and
Thick paper 1 Valid
2: (Normal temperature / Low temperature) Valid (except for
Envelope)
3: (Normal temperature) Plain paper and Thick paper 1
Valid
4: (Normal temperature / Low temperature)Plain paper
5: (Normal temperature) Plain paper
6: (Normal temperature) Valid (except for Envelope)
1YY
08 Setting
mode
Process Fuser 2100 - Temperature setting of
warming-up (Center
thermistor)
5 0-14 M 0: 140 degrees C 1: 145 degrees C 2: 150 degrees C 3:
155 degrees C 4: 160 degrees C 5: 165 degrees C 6:
170 degrees C 7: 175 degrees C 8: 180 degrees C 9:
185 degrees C 10: 190 degrees C 11: 195 degrees C
12: 200 degrees C 13: 205 degrees C 14: 210 degrees C
1YY
08 Setting
mode
Process Fuser 2101 - Temperature setting of
warming-up (Side
thermistor)
5 0-14 M 0: 140 degrees C 1: 145 degrees C 2: 150 degrees C
3: 155 degrees C 4: 160 degrees C 5: 165 degrees C
6: 170 degrees C 7: 175 degrees C 8: 180 degrees C
9: 185 degrees C 10: 190 degrees C 11: 195 degrees C
12: 200 degrees C 13: 205 degrees C 14: 210 degrees
C
1YY
08 Setting
mode
Process Fuser 2111 - Pre-running time
(Normal temperature)
0 0-18 M 0: Disabled 1: 1 sec. 2: 2 sec. 3: 3 sec. 4: 4 sec. 5: 5
sec. 6: 6 sec. 7: 7 sec. 8: 8 sec. 9: 9 sec. 10: 10 sec. 11:
15 sec. 12: 20 sec. 13: 25 sec. 14: 30 sec. 15: 40 sec.
16: 50 sec. 17: 60 sec. 18: 150 sec.
1YY
08 Setting
mode
Process Fuser 2120 - Fuser roller
temperature in ready
status (Side thermistor)
8 0-12 M 0: 140 degrees C 1: 145 degrees C 2: 150 degrees C
3: 155 degrees C 4: 160 degrees C 5: 165 degrees C
6: 170 degrees C 7: 175 degrees C 8: 180 degrees C
9: 185 degrees C 10: 190 degrees C 11: 195 degrees
C 12: 200 degrees C
1YY
08 Setting
mode
Process Fuser Temperature drop
setting in ready
status (Side
thermistor)
2121 0 The first drop 4 0-10 M Setting value x -5 degrees C: from 0 degrees C to -50
degrees C
4YY
08 Setting
mode
Process Fuser Temperature drop
setting in ready
status (Side
thermistor)
2121 1 The second drop 4 0-10 M Setting value x -5 degrees C: from 0 degrees C to -50
degrees C
4YY
08 Setting
mode
Process Fuser Temperature drop
setting in ready
status (Side
thermistor)
2121 2 The third drop 4 0-10 M Setting value x -5 degrees C: from 0 degrees C to -50
degrees C
4YY
08 Setting
mode
Process Fuser Temperature drop
setting in ready
status (Side
thermistor)
2121 3 The fourth drop 4 0-10 M Setting value x -5 degrees C: from 0 degrees C to -50
degrees C
4YY