05/08 Mode Element Sub element Item Subitem Code
Sub-
code
Details
Default
value
Acceptable
value
SRAM Contents
Proce
dure
20L
23L/
25L
20H
23H/
25H
08 Setting
mode
Process Fuser 2090 - Printing temperature
drop control
1 0-6 M 0: Invalid
1: (Normal temperature / Low temperature) Plain paper and
Thick paper 1 Valid
2: (Normal temperature / Low temperature) Valid (except for
Envelope)
3: (Normal temperature) Plain paper and Thick paper 1
Valid
4: (Normal temperature / Low temperature)Plain paper
5: (Normal temperature) Plain paper
6: (Normal temperature) Valid (except for Envelope)
1YY
08 Setting
mode
Process Fuser 2100 - Temperature setting of
warming-up (Center
thermistor)
5 0-14 M 0: 140 degrees C 1: 145 degrees C 2: 150 degrees C 3:
155 degrees C 4: 160 degrees C 5: 165 degrees C 6:
170 degrees C 7: 175 degrees C 8: 180 degrees C 9:
185 degrees C 10: 190 degrees C 11: 195 degrees C
12: 200 degrees C 13: 205 degrees C 14: 210 degrees C
1YY
08 Setting
mode
Process Fuser 2101 - Temperature setting of
warming-up (Side
thermistor)
5 0-14 M 0: 140 degrees C 1: 145 degrees C 2: 150 degrees C
3: 155 degrees C 4: 160 degrees C 5: 165 degrees C
6: 170 degrees C 7: 175 degrees C 8: 180 degrees C
9: 185 degrees C 10: 190 degrees C 11: 195 degrees C
12: 200 degrees C 13: 205 degrees C 14: 210 degrees
C
1YY
08 Setting
mode
Process Fuser 2111 - Pre-running time
(Normal temperature)
0 0-18 M 0: Disabled 1: 1 sec. 2: 2 sec. 3: 3 sec. 4: 4 sec. 5: 5
sec. 6: 6 sec. 7: 7 sec. 8: 8 sec. 9: 9 sec. 10: 10 sec. 11:
15 sec. 12: 20 sec. 13: 25 sec. 14: 30 sec. 15: 40 sec.
16: 50 sec. 17: 60 sec. 18: 150 sec.
1YY
08 Setting
mode
Process Fuser 2120 - Fuser roller
temperature in ready
status (Side thermistor)
8 0-12 M 0: 140 degrees C 1: 145 degrees C 2: 150 degrees C
3: 155 degrees C 4: 160 degrees C 5: 165 degrees C
6: 170 degrees C 7: 175 degrees C 8: 180 degrees C
9: 185 degrees C 10: 190 degrees C 11: 195 degrees
C 12: 200 degrees C
1YY
08 Setting
mode
Process Fuser Temperature drop
setting in ready
status (Side
thermistor)
2121 0 The first drop 4 0-10 M Setting value x -5 degrees C: from 0 degrees C to -50
degrees C
4YY
08 Setting
mode
Process Fuser Temperature drop
setting in ready
status (Side
thermistor)
2121 1 The second drop 4 0-10 M Setting value x -5 degrees C: from 0 degrees C to -50
degrees C
4YY
08 Setting
mode
Process Fuser Temperature drop
setting in ready
status (Side
thermistor)
2121 2 The third drop 4 0-10 M Setting value x -5 degrees C: from 0 degrees C to -50
degrees C
4YY
08 Setting
mode
Process Fuser Temperature drop
setting in ready
status (Side
thermistor)
2121 3 The fourth drop 4 0-10 M Setting value x -5 degrees C: from 0 degrees C to -50
degrees C
4YY
© 2013-2017 TOSHIBA TEC CORPORATION All rights reserved
14-1-31
e-STUDIO2006/2306/2506/2007/2307/2507
SELF-DIAGNOSIS CODE (03/04/05/08 CODE)