EasyManua.ls Logo

Toshiba Strara CTX Series - Page 119

Toshiba Strara CTX Series
290 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Strata CTX670 Installation
3-45
Strata CTX I&M September 2002
8. Connect the fibre optic cables
Pass the fibre optic cable through the protective tube.
Route the tube through the clamp attached to the inner cabinet wall and secure the clamp
Attach fibre to the SC connectors on the ROMS1A daughterboard.
The TX side of the Master connects to the RX side of the slave.
The RX side of the Master connects to the TX side of the slave.
TIU recommends that the cables be marked within the cabinet for ease of maintenance.
Observe the minimum bend radius of 30mm.
9. Restore power.
The RRCU PCB and its controls and connectors are shown in Figure 3-32 and Table 3-7.
Figure 3-32 Remote Expansion Cabinet Printed Circuit Board (RRCU1A)
Table 3-7 RRCU Controls
The ROMS subassembly and fibre optic cable connectors is shown in Figure 3-33. Table 3-8 lists the
fibre optic cable specifications.
Control/Indicator/Connector Type of Component Description
Jumper Plug P10 3-terminal Jumper Plug Master Mode (M connections)
Jumper Plug P10 Slave Mode (S connections)
4356
RRCU1A
Backplane Connector
P8 P9P7P6 M2 S2S1M1
Master 1
Connect to
Base Cabinet
Master 2
Connect to
Base Cabinet
Slave 1
Connect
to MSBU
Slave 2
Connect
to MSBU
RS-232
Port
ROMS1A
MS
MS
P11
P10
P4
P3
P2P1

Table of Contents