STE 80720 
– 10-5  – 
OPERATOR’S MANUAL
series  Robot Controller
  Keys operative in this mode and their operations are shown below. 
 
Key Descriptions 
ALT +  ↓  
Used to display the next page.    If the cursor is located at the 
final page, the page will not change over. 
ALT + ↑  
Used to display the previous page.    If the cursor is located at 
the top page, the page will not change over. 
ESC  
Used to return the system to the utility display. 
 
  Operation of each command menu is shown below. 
 
Menu Descriptions 
[AUXn]  Each time this key is pressed, the solenoid state changes from 
ON to OFF or vice versa.    For the double solenoid, the state of 
two (2) ports are changed over alternately. 
 
 (3) Cautions 
•  The output signal port and solenoid type corresponding to each command 
menu should be defined in the user parameter file in advance.    For more 
information, see the User Parameter Manual. 
•  During emergency stop, auxiliary signals can be turned on and off. 
The initial state at power ON, including signals which are set for the double 
solenoid, is OFF.