EasyManua.ls Logo

TR-Electronic CES-65 - Page 98

TR-Electronic CES-65
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameterization and configuration
TR-Electronic GmbH 2007, All Rights Reserved Printed in the Federal Republic of Germany
Page 98 of 131 TR - ECE - BA - DGB - 0060 - 05 02/23/2017
Overview of operating parameters
see note on page 89
Parameter
Data type
Byte
Not supported!
Format
Description
Count direction
bit
9
page 98
page 108
Short Diagnostics
bit
9
page 98
page 111
Commissioning diagnostics
bit
9
page 98
page 108
Teach-In function
unsigned8
10
X
page 99
page 109
Total measuring range
unsigned32
11 14
page 99
page 114
Revolutions numerator
unsigned32
15 18
page 99
page 114
Revolutions denominator
unsigned16
19 20
page 99
page 114
Code SSI-Interface
unsigned8
21
page 100
page 117
Code PROFIBUS-Interface
unsigned8
22
page 100
page 117
Preset 1
unsigned32
23 26
page 100
page 117
Preset 2
unsigned32
27 30
page 100
page 117
Lower limit switch
unsigned32
31 34
page 101
page 118
Upper limit switch
unsigned32
35 38
page 101
page 118
Data bits SSI-Interface
unsigned8
39
page 101
page 118
Bit coded operating parameters
DDLM_Set_Prm
Byte
9
Bit
7 0
Data
2
7
2
0
x = default setting
Bit
Definition
= 0
= 1
Page
0
Count direction
ascending position values
for clockwise rotation
X
ascending position
values counter-
clockwise rotation
108
1
Short Diagnostics
yes
no
X
111
2
Commissioning
diagnostics
switched off
X
switched on
108

Table of Contents