Trane TCONT900AC43UA - Electrical Connections to a Communicating Systems Air Handler in Communicating Mode

Trane TCONT900AC43UA
336 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AC - A 8
Electronic Air Cleaners
STEP 1
Remove electrical power going into the air handler.
STEP 2
On the communicating systems air handler, remove the blower access panel.
STEP 3
Connect Red stripped wire to "R" terminal on the air handler terminal strip.
STEP 4
Connect Blue stripped wire to "B" terminal on the air handler terminal strip.
STEP 5
Connect the brown wire from the air cleaner harness to the "D" terminal on the Communicating Systems Air
Handler.
STEP 6
Connect the Black wire from the air cleaner wire harness to earth ground by attaching the wire to a grounded
screw that is connected to the metal air handler chassis.
STEP 7
The Green and White wires on the air cleaner wiring harness are unused in this application and should be
insulated separately.
STEP 8
Replace the blower access panel.
STEP 9
Reconnect electrical power to the air handler.
STEP 10
Check air cleaner and air handler operation.
Electrical Connections To A Communicating Systems Air Handler In Communicating Mode
WARNING
Hazardous Voltage. Disconnect all electric power, including remote disconnects before servicing. Follow
proper lockout/tagout procedures to ensure the power can not be inadvertently energized. Failure to discon-
nect power before servicing could result in death or serious injury.