EasyManua.ls Logo

Trane TCONT900AC43UA - Pre-Filter Settings; Collection Cells Cleaning Setting; Field Charger Power Level Setting

Trane TCONT900AC43UA
336 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AC - A 17
Electronic Air Cleaners
Pre-Filter Settings
One or more of the Green LED’s will come on indicat-
ing the Pre-Filter cleaning time setting. Repeatedly
press the Reset button to cycle through the time op-
tions for the Pre-Filter cleaning cycle until the desired
setting is displayed. Press the Power button once to
accept that setting and move to the Collection Cells
cleaning settings.
To change any of the settings, press the Power but-
ton once. Follow the below instructions for setting the
pre-filter and collection cell timers. For a Communi-
cating Air Cleaner, be sure the Comfort Control filter
timer is set to “Auto Detect” before changing the set-
tings on the air cleaner. To determine whether or not
the unit is a communicating unit, review the Amber
light shown in Figure 1a on page A2.
Collection Cells Cleaning Setting
One or more of the Yellow LED’s will come on indicat-
ing the Collection Cells cleaning time setting. Repeat-
edly press the Reset button to cycle through the time
options for the Collection Cells cleaning cycle until
the desired setting is displayed. Press the Power
button once to accept that setting and move to the
Power level settings.
Note: If two air cleaners are connected on the same
system, set all timers on both air cleaners to the same
settings. The comfort control will only report one air
cleaner timer and this methodology will allow the air
cleaners to remain on the same cleaning schedule.
Field Charger Power Level
The Red LED lights are used to set the power level of
the Field Charger for maximum, medium, or minimum.
The number of illuminated Red LED lights indicates
the current setting. The factory setting is for maxi-
mum.
Lower settings will reduce the slight sound emitted
by the unit with minimal loss of air cleaning efficiency,
if desired. Lower settings will also further reduce the
very low ozone produced by the Air Cleaner. The U.S.
Food and Drug Administration recommends indoor
ozone concentrations should not exceed 50 parts per
billion. The Air Cleaner will contribute only 5 parts per
billion at the factory setting and can be reduced to .3
parts per billion at the minimum setting.
Field Charger Power Level Setting
One or more of the Red LED lights will illuminate. To
change the power level setting, press the Reset but-
ton until the desired setting is indicated.
To save your new settings and exit the Set-Up mode,
press and hold Both the Power and filter Reset but-
tons for a minimum of 5 [6] seconds.