CA - A 6
Charge Assist™
Step 2
Enter Stabilization Routine - The CHARGING
(STABILIZING) Amber LED (Figure 10) will begin to
flash.
Figure 10
The CA control will then indicate the time it will take
for the refrigerant system to stabilize by flashing its
CHARGING (STABILIZING) Amber LED. (See
SUMMARY (Figure 11) for flash rate details.)
The CA control may run the system for up to twenty
minutes to insure the refrigerant system is at a steady
operating state. Once the system is at a steady
operating state the CA control will enter the Charging
Routine.
Step 3
Charging Routine - Charge Assist™ will follow one
of the following routines: Charged, Add, or Recover.
Figure 11
CHARGED Routine
If the CA control determines the system is correctly
charged, the CHARGING (STABILIZING) Amber LED
will be turned OFF and the CHARGED Green LED
will be turned ON (Figure 12).
Figure 12
ON
OFF
The CA control will then exit the charge assist cycle
and return the control of the system to the
Communicating Comfort Control. The Status Green
LED will be slowly flashing. The CHARGED Green
LED will stay ON for 1 hour.