37
TROUBLESHOOTING
Issue / Recommendation
Weight reads out lower at one end of the weighing platform than the other end.
- Check for any type of mechanical binding or impingement of scale that is displaying the
lower weight
- Check underneath the scale for any obstructions or foreign debris
- Make sure that the scale feet are not screwed in so far as to restrict downward move-
ment of the scale.
- Adjust platform corners using variable trimmer junction box (if supplied)
Indicator displays six small zeros.
- Scale is overloaded. Remove weight from scale.
- Cut, damaged, loose, pinched cable between indicator and platform or within platform
with multiple load cells
- Load cell damaged on scale platform
- Internal fault with indicator; call Transcell Tech Support
Display is erratic.
- Check underneath the scale platform for any obstructions or foreign debris
- Check AC power (brownout and/or noisy)
- Electromagnetic interference (EMI)