30
FILLING (B3 = 2) Same as Automatic Mode except for the digital output logic (see table
below).
CONTINUOUS (B3 = 3) Same as Automatic Mode except that you need not press the F1
key to begin each batch.
Here is a summary table of the digital output states for all modes except Filling:
Weight Reading
OUT1
OUT2
OUT3
OUT4
wt SP1
ON
OFF
OFF
OFF
SP1 < wt SP2
OFF
ON
OFF
OFF
SP2 < wt SP3
OFF
OFF
ON
OFF
SP3 < wt SP4
OFF
OFF
OFF
ON
SP4 < wt
OFF
OFF
OFF
OFF
Here is a summary table of the digital output states for Filling mode:
Weight Reading
OUT1
OUT2
OUT3
OUT4
wt SP1
ON
ON
ON
ON
SP1 < wt SP2
OFF
ON
ON
ON
SP2 < wt SP3
OFF
OFF
ON
ON
SP3 < wt SP4
OFF
OFF
OFF
ON
SP4 < wt
OFF
OFF
OFF
OFF
Note: ON means “Active” and OFF means “Cutoff”
LEDs on the front panel designate which digital output is Active:
Weigh-In/Weigh-Out (F30 = 8)
The function captures both the inbound and the outbound weights of vehicles. As part of the
weigh-out process, the net gain or loss is calculated, and a report is automatically printed. Up to
256 individual vehicle weights can be stored via ID number.
Use the C/CE key at any time to exit a function. If no key entry is made within a few seconds,
the indicator automatically reverts to normal operating mode.
Weigh-In
1. With the truck on the scale, press the F1 key. “Ent Id” will be displayed.
2. Key-in in the vehicle ID number (up to 999999) and then press Enter. The indicator
will display “In”.
3. If a printer is connected, a ticket will automatically be printed.