The host can select a unique ID separation of one ID or two IDs. The reader default operation is for a
unique ID separation of one ID and a uniqueness timeout of two minutes. You can disable the uniqueness
check using Command #40 Transmit All ID Codes. In this case, every tag ID received is transmitted
without regard to uniqueness. You can reinstate uniqueness checking with commands #4100 or #4101
Select ID Separation.
Note: The MPRX internal timing varies depending on the operative tag read mode and the type of
tag in the read field.
Refer to section “40 Transmit All ID Codes” on page 5–63 “and section “529 Display Presence Input
Status” on page 5–70.
To set ID separation parameters
1. Ensure that the host device is in command mode.
2. Enter Command #4100 to select a separation of one ID; enter Command #4101 to select a
separation of two IDs. Press ENTER.
Reports
The MPRX can be configured to transmit presence without tag reports and input status change reports.
A presence without tag report is transmitted in data mode only, and only if the system has a presence
detector. This report is sent if a presence is detected without the detection of a valid tag ID. Refer to
sections “529 Display Presence Input Status” on page 5–70 and “690N Select Presence Without Tag
Report Option” on page 5–78.
To set presence reporting
1. Ensure that the host device is in command mode.
2. Enter Command #529 to display presence input status and press ENTER. P0 indicates presence
without tag reports disabled (factory default), and P1 indicates presence without tag reports
enabled.
3. Enter Command #6901 to enable presence without tag reports, or enter Command #6900 to
disable presence without tag reports (factory default). Press ENTER.
To set input status change reporting
1. Ensure that the host device is in command mode.
2. Enter Command #560 to display input status change report options and press ENTER.
E0 input status change reports disabled (factory default)
E1 input status change reports enabled
M0 reporting disabled (factory default)
M1 changes on input 0 reported
M2 changes on input 1 reported
M3 changes on either input reported