NORMAL.DOT Gespeichert in:G:\Support\Dokumentationen_CDs\8003Speedy\Service Manual\Servicemanual 8003.doc Gespeichert am:2003/03/10
max Version 14
Seite 11 von 87
T H E U L T I M A T E M A R K
I N G S O L U T I O N
Safety Interlock System
Your Speedy is equipped with an integrated safety interlock system which cuts off
the power of the laser tube immediately as soon as one of the doors is open ed.
CAUTION
Do not attempt to alter the interlock system as that could result in
hazardous radiation exposure.
CAUTION
Technicians who are performing service procedures must be trained in
laser safety, and if they are defeating interlocks, they must wear laser
protective eyewear designed for the 10,6µm CO
2
laser energy.
The top door, front door and the maintenance access panel are interlocked. If the
interlocks are defeated access to laser class IV radiation is possible through any of
these doors.
All other covers are not interlocked.
CAUTION
When a non interlocked cover is opened (and the machine is powered)
access to class IV laser radiation is possible.
These covers are labeled with „DANGER: INVISIBLE LASER RADIATION
WHEN OPEN. AVOID EYE OR SKIN EXPOSURE TO DIRECT OR
SCATTERED RADIATION“