NORMAL.DOT Gespeichert in:G:\Support\Dokumentationen_CDs\8003Speedy\Service Manual\Servicemanual 8003.doc Gespeichert am:2003/03/10
max Version 14
Seite 35 von 87
I N D I V I D U A L M A R K I N G S Y S T E M S
Tab „acceleration“ in the service setup
The default parameters are:
X: 9
Y: 4
Vector: 1
Circle: 1
Altering the default parameters can be useful if there is a problem on one of the axis
(tracking errors) and you want to keep the machine in operation. In this case reduce
the acceleration (and eventually the top speed).