Bottom Density – Measurement Entry
Bottom density values may be obtained by using the gauge to record an
actual measurement. Follow the instructions from the Bottom Density –
Keypad Entry description on the previous page until reaching the Select
method of... display.
Press 〈2〉 for measurement entry. The display will be:
Input the number of readings to be taken and averaged. Press
〈START/ENTER〉 for the display:
Prepare the site for measurement. Position the gauge and press
〈START/ENTER〉. The display will be:
After counting down to zero, the display will be:
If more than one reading is to be taken, move the gauge to the next location
and press
〈START/ENTER〉. The gauge will repeat the above sequence
for each reading. When all the readings are completed, the display will be:
average (1-20)?
x
Press ENTER
Ti
me
:
x
m
i
n.
Set rod to BS &
Press
START
Reading # 1
Depth: BS
Time:xx sec.
WD:xxxxx
PCF
Move gauge and
press START
R
ea
ding(s
)-
xxxxx
PCF
Press ENTER