EasyManua.ls Logo

Troxler 4140 - Troubleshooting Common Issues

Troxler 4140
114 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
A-2
TROUBLESHOOTING
See safety warnings on page 2-2.
GYRATORY COMPACTOR DOES NOT TURN ON
✓
Ensure that the unit is plugged in.
✓
Check that the power switch is in the ON position.
✓
Check that the fuse for the wall outlet is not blown.
✓
Check the power to the wall outlet.
CONTROL UNIT DISPLAYS KEYPAD ERROR
✓
A key is stuck. Check the keypad. To replace, call a Troxler
Service Center.
MOVING PARTS ARE NOT MOVING
✓
Check that all shrouds are in place.
✓
Ensure the unit is turned on.
✓
A switch may be broken. Check the shroud and emergency
switches.
CONTROL UNIT DISPLAYS: A Panel Interlock Switch is
Open
✓
Check that all the shrouds are properly mounted and secured.
CONTROL UNIT DISPLAYS: Emergency Switch Is Closed.
Rotate To Open
✓
The emergency stop feature is active. To deactivate, rotate the
〈EMERGENCY〉 stop button clockwise. The control unit
returns to the Machine Idle screen.