SECOND
Description
This variable reads/writes the second data via the Real Time Clock (RTC). Two-digits (00~59) second
format is supported by RTC.
Syntax
Write attribute: SECOND = 12
Read attribute: A = SECOND
Range: 00~59
Example
Sample code
DOWNLOAD "SetSecond.BAS"
REM *****Set Second Parameter to RTC*****
SECOND=59
EOP
SetSecond
Sample code
DOWNLOAD "DEMO.BAS"
SIZE 4,1
GAP 0,0
DIRECTION 1
CLS
REM *****Read Second parameter form RTC*****
SECOND$=STR$(SECOND)
SEC=SECOND
REM *****Print*****
TEXT 10,10,"3",0,1,1,"SECOND1="+SECOND$
TEXT 10,50,"3",0,1,1,"SECOND2="+STR$(SEC)
TEXT 10,90,"3",0,1,1,"SECOND3="+STR$(SECOND)
PRINT 1
EOP
DEMO
Result
See Also
~!C, MONTH, DATE, DAY, HOUR, MINUTE, SECOND

Table of Contents

Other manuals for TSC TTP-345

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TSC TTP-345 and is the answer not in the manual?

TSC TTP-345 Specifications

General IconGeneral
Print MethodThermal Transfer
Resolution300 dpi
Max Print Speed5 ips
Max Print Length90" (2286 mm)
Memory8 MB Flash
InterfaceUSB 2.0, RS-232
Power SupplyExternal universal switching power supply