Chapter 13. Groups of parameters
Param.
No.
Name Unit
Access
level
Description
10.08 Ogon freq min Hz 2
Generator frequency below which relay K1 is
activated
10.09 Ogon freq opt Hz 2
Generator frequency above which the relay K1 or K2
is switched off
10.10 Ogon Urms max V 2
The voltage above which the K2 relay is switched on
and the K1 relay switched off, if necessary
10.11 Ogon t1 s 2 The minimum activation time of the K2 relay
10.12 Load default - 2 Loading default parameters
10.13 Power hysteresis - 2 MPPT parameter
10.14 Global mppt scan - 0
Time between global MPPT scans.
0 min = disable Global MPPT
10.15 windType - 2
Algorithm of wind input loading depending on wind
speed
10.16 antiIsland - 2 Protection against island operation
10.17 Ugadna start b - 2 Energy Guard module parameter
10.18 Uganda start ni - 2 Energy Guard module parameter
10.19 Uganda start pea - 2 Energy Guard module parameter
10.20 Erase all plots - 2 Deleting all charts
10.21 Set 0-999W W 2 Manually setting the energy produced
10.22 Set 0-999kW kW 2 Manually setting the energy produced
10.23 Set 0-999MW MW 2 Manually setting the energy produced
10.24 Erase power - 2 Resetting the power energy value
10.25 Set run day - 2 Manually setting the working time
10.26 Set run hour - 2 Manually setting the working time
10.27 Erase run time - 2 Resetting working time
10.28 Erase events - 2 Resetting failure logs
10.29 Phase guard - 1
Phase designation when using Energy Guard module:
0 - Energy Guard OFF
1 - L1 phse
2 - L2 phase
3 - L3 phase
4 - “On-grid bat” mode (see chapter 12.2)
10.30 MAC 1 - 2 MAC address
10.31 MAC 2 - 2 MAC address
10.32 MAC 3 - 2 MAC address
10.33 MAC 4 - 2 MAC address
10.34 MAC 5 - 2 MAC address
10.35 MAC 6 - 2 MAC address
10.36 Inv. Name 1 - 2 Inverter serial number
10.37 Inv. Name 2 - 2 Inverter serial number
10.38 Inv. Name 3 - 2 Inverter serial number
10.39 Inv. Name 4 - 2 Inverter serial number
10.40 Inv. Name 5 - 2 Inverter serial number
PS100 – User manual 61