EasyManuals Logo
Home>TYM>Tractor>T390

TYM T390 Service Manual

TYM T390
301 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #257 background imageLoading...
Page #257 background image
400Maximum pressure Kgf/
(psi)
160System pressure Kgf/
(psi)
35Normal flow /min
9 cc/min
A and B port leak
Oil temperature:50(122)
Under a load of 100Kgf/
THF 500Recommended fluid
-20~80Operating temperature range
45Maximum flow /min
3. REMOTE HYDRAULIC CONTROL VALVE
3.1 SPECIFICATIONS
9-45
3.1 HYDRAULIC CIRCUIT
Fig. 9-69 Remote hydraulic pump
P:From pump
T:To tank
A:High pressure port
B: Return port

Table of Contents

Other manuals for TYM T390

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TYM T390 and is the answer not in the manual?

TYM T390 Specifications

General IconGeneral
BrandTYM
ModelT390
CategoryTractor
LanguageEnglish

Related product manuals