-After soaking,rise it in fresh water.
-Let it in a shaded and well ventilated place.
Forced drying by heat or compressed air is
prohibited.
Note:
Water applied to rinse the element should not
have a pressure of more than 2.8kgf/
(39.8psi).
An element which has been washed 5 times
must be replaced with a new one.
5.ELEMENT INSTALLATION
Install the element in the reverse order of
disassembly,but follow these instructions.
1) Each tightening bolt must be secured and
care must be taken not to miss the packing
and washers.
2) Before installing the element,clean the
rubber packing on the top of the element.
Note:
The wing bolt retaining the element should be
tightened sufficiently so that it will not become
loose during operation