11-7
Service instructions
and remarks
Usable limitsStandard value
for reassembly
Nominal
dimensions
Part names and
inspection items
2) Dynamic lift
1300 T390/T400/T430/T450
3) Cylinder case bush
Wear limit: 0.2 Ø 60.2 Ø 60 60 ×65 ×50Right side
Wear limit: 0.2 Ø 55.2 Ø 55 55 ×60 ×50Left side
4) Flow divider
under a flow rate of
0.9 /min
15 f/ overSetting pressure of PTO
clutch port
Pressure:1 f/ (psi)5.0~6.0 cc(0.305 cu in)Flow through PTO
clutch port
5) Flow divider assembly
2 times / secSwitch-over frequency limit
2.1 ARated current
15.0 15.5 Free length of change over valve spring
0.025 Clearance between change over valve and casing
0.021 Clearance between sequential valve spool and casing
29.0 30.0 Free length of pressure reducing valve spring
DC 12 VRated voltageSolenoid
21.5 22.0 Sequence valve
spring free length.