Technical data
Applic. No.
Application (process gas type)
Measuring range
(Wobbe index)
Measuring accuracy
[Wobbe index]
011
5.2 – 10.5 MJ/m3/1.4 – 2.9 kWh/1,250 – 2,500
3
±2% FS Not used
012
4.2 – 12.6 MJ/m3 I 1.2 – 3.5 kWh/1,000 – 3,000
3
±2% FS Not used
017
4.0 – 7.0 MJ/m3/1.1 – 1.9 kWh/950 – 1,650 kcal/100 –
3
±1.5% FS ±1.5% MV
019
0 – 90 MJ/m3 I 0 – 25 kWh/0 – 21,500 kcal/0 – 2,290
±3% FS ±2% FS
020
0 – 118 MJ/m3 I 0 – 32.8 kWh/0 – 28,180 kcal/0 –
±3% FS ±2% FS
021
> 800 MJ/m3 I > 222 kWh/> 191,000 kcal/> 20,340
3
±3% FS ±2% FS
024
0 – 10 MJ/m3 I 0 – 2.8 kWh/0 – 2,390 kcal/0 – 250
3
±3% FS ±2% FS
025
8.4 – 12.4 MJ/m3 I 2.3 – 3.4 kWh/2,010 – 2,960
3
±1.5% FS ±1.5% MV
026
12.5 – 19 MJ/m3 I 3.5 – 5.3 kWh/2,990 – 4,540
3
±1.5% FS ±1.5% MV
Testing and certification
027
Mixed gas LPG (Liquefied Petroleum Gas) + air
(compliance)
32 – 58 MJ/m3 I 8.9 – 16.1 kWh/7,640 – 13,850
±1% FS ±1% MV
029
42 – 59 MJ/m3 I 11.7 – 16.4 kWh/10,030 – 14,090
kcal/1,070 – 1,500 BTU/ft
3
±1% FS ±1% MV
030
70 – 87 MJ/m3 I 19.4 – 24.2 kWh/16,720 – 20,780
kcal/1,780 – 2,220 BTU/ft
3
±1% FS ±1% MV
MJ: Mega Joule; BTU: British Thermal Unit; FS: Full Scale; MV: Measured Value