Power unit
PA205R
CPU unit
CJ1M-CPU11
Input unit
CJ1W-ID211
Output unit
CJ1W-OD211
F159 End coverF159 F159
Three load cells are connected in parallel
0.58[A] 0.08[A] 0.10[A] 0.56[A] 0.56[A] 0.56[A]Power consumption →
Source capacity
5[V] 5[A]
Unit type Unit name Qty Power consumption (A)
CPU unit CJ1M-CPU11 1 0.58A
Input unit CJ1W-ID211 1 0.08A
Output unit CJ1W-OD211 1 0.10A
Weight Module
F159 3 1.68A
Consumption(A)
Calculation
0.58 + 0.08 + 0.10 + 1.68
Result
2.44A(≦ 5A)