6.WEIGHING MODE SETTING AND OPERATION
66
6-1-3. Weighing Mode
This register defines settings for Feed/Discharge control. You can select one of
three options (Feed, Discharge, or Relay selection).
If you choose “2: Relay selection”, specify the type of Weighing mode by
selecting Feed/Discharge bit (6th bit of n CH): “1” for Discharge control, “0” for
Feed control.
10
0
10
0
10
0
10
0
Near zero comparison
m+27
2Relay selection
1Discharge control
0Feed control
Upper/Lower limit comparison
Over/Under comparison
Weighing mode