EasyManuals Logo

Unipulse F159 User Manual

Unipulse F159
126 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #37 background image
3.DATA EXCHANGE WITH CPU
28
3-2-4. Register Allocations for Weighing Control
m = D20000 + Unit No. × 100
m
10
3
10
2
10
1
10
0
Upper limit 00000 - 99999
m+1
10
4
m+2
10
3
10
2
10
1
10
0
Lower limit 00000 - 99999
m+3
10
4
m+4
10
3
10
2
10
1
10
0
Near zero 00000 - 99999
m+5
10
4
m+6
10
3
10
2
10
1
10
0
Set point 1 00000 - 99999
m+7
10
4
m+8
10
3
10
2
10
1
10
0
Set point 2 00000 - 99999
m+9
10
4
m+10
10
3
10
2
10
1
10
0
Free fall
compensation
0000 - 9999
m+11
10
2
10
1
10
0
Over
000 - 999
m+12
10
2
10
1
10
0
Under
000 - 999
m+13
10
3
10
2
10
1
10
0
Final
00000 - 99999
m+14
10
4
m+15
10
3
10
2
10
1
10
0
Preset tare
value
00000 - 99999
m+16
10
4
m+17
10
4
Undefined
m+18
10
4
Undefined
m+19
10
4
Undefined