3.DATA EXCHANGE WITH CPU
32
Weighing function 2
10
0
10
0
10
0
10
0
Sign convention for discharge control
1Sign of Net weight not reversed
0Sign of Net weight reversed
Completion signal output mode
2Complete signal turns on when SP3 turns on, and
remains on until Compare time expires, or,
Complete signal turns on when reading becomes
“stable” and remains on until Complete output
time expires.
1After Compare time expires, Complete signal
turns on when reading becomes “stable” and
remains on until Complete output time expires.
0Complete signal turns on when Compare time
expires, and remains on until Complete output
time expires.
Upper/Lower limit comparison mode
1Comparison when Judge input turns ON
0Always
Over/Under comparison mode
3Comparison when complete signal
turns ON. Weight will be frozen.
2Comparison when complete output
turns ON.
1Comparison when Judge input
turns ON
0Always