6.WEIGHING MODE SETTING AND OPERATION
81
10
0
10
0
10
0
10
0
Near zero comparison
m+27
Upper/Lower limit comparison
Over/Under comparison
Weighing mode
2:Comparison OFF
1:Net weight
0:Gross weight
2:Comparison OFF
1:Net weight
0:Gross weight
4:ON when |Net weight|
  <= Near zero set value
3:ON when |Gross weight|
  <= Near zero set value
2:Comparison OFF
1:ON when Net weight
  <= Near zero set value
0:ON when Gross weight
  <= Near zero set value
10
0
10
0
10
0
10
0
Sign convention for discharge control
m+28
3:Comparison when complete signal
turns ON. Weight will be frozen.
2:Comparison when complete output
turns ON.
1:Comparison when Judge input
turns ON
0:Always
Complete signal output mode
Upper/Lower limit comparison mdoe
Over/Under comparison mode
1:Comparison when Judge input
turns ON
0:Always