7.LADDER DIAGRAM
89
A200.11
000001
P_First_Cycle
MOV
(021)
#0
D20013
ON flag is set to allow
(000018)
Final
MOV
(021)
#0
D20014
Final
MOV
(021)
#0
D20015
Preset tare value
MOV
(021)
#0
D20016
Tare set value
MOV
(021)
#0050
D20020
Compariton Inhibit Time
MOV
(021)
#0150
D20021
Compare time
MOV
(021)
#0300
D20022
Complete output time
MOV
(021)
#0100
D20023
Auto jog timer
MOV
(021)
#0101
D20024
AZ times/Judging times
MOV
(021)
#9800
D20025
FF CPS. regulation
MOV
(021)
#0000
D20026
FF CPS. regulation
MOV
(021)
#0000
D20027
Weighing function 1
MOV
(021)
#0000
D20028
Weighing function 2
Initial settig write
MOV
(021)
#0141
D20029
Weighing function 3
MOV
(021)
#0012
D20030
Output selection
MOV
(021)
#0000
D20031
Restriction on
single cycle execution
(lower 4 digits)
(lower 4 digits)
(upper 1 digit)
(upper 1 digit)
(lower 4 digits)
(upper 1 digits)
tare subtraction