EasyManua.ls Logo

USR IOT USR-DR404 - At+H; At+Wsqy; At+Htpmode

USR IOT USR-DR404
86 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
USR-DR404 user manual www.usriot.com
Jinan USR IOT Technology Limited www.usriot.com
74
4.3.4.39. AT+H
Function: Help command
Format:
Query : AT+H<CR>
+ok=<commod help><CR>< LF ><CR>< LF >
Parameters: commod help: Command line instructions
4.3.4.40. AT+WSQY
Function: Query/Set RSSI threshold(percentage) to switch among three AP in STA mode
Format:
Query : AT+ WSQY<CR>
+ok=<ret><CR>< LF ><CR>< LF >
Setting: AT+ WSQY=< ret><CR>
+ok<CR>< LF ><CR>< LF >
Parameters:
ret:
The percentage of RSSI threshold. If the RSSI threshold is 50%, the setting should be AT + WSQY = 50 <CR>”
Note: If set to 100, the module will not switch WIFI network automatically. If the customer uses only one STA
parameter, be sure to set this parameter to 100.
4.3.4.41. AT+HTPMODE
Function: Query/Set HTTP Client mode parameters configuration way (new/old)
Format:
Query : AT+HTPMODE<CR>
+ok=<type><CR>< LF ><CR>< LF >
Setting: AT+ HTPMODE=<type><CR>
+ok<CR>< LF ><CR>< LF >
Parameters:
type: Authentication mode, including
new : New HTTP Client mode parameters configuration way
old: old HTTP Client mode parameters configuration way

Table of Contents