USR-DR404 user manual www.usriot.com
Jinan USR IOT Technology Limited www.usriot.com
4.3.4.53. AT+WTPWR
Function: Set module’s transmit power
Format:
Query : AT+ WTPWR <CR>
+ok=<sta.><CR>< LF ><CR>< LF >
Setting: AT+ WTPWR =<sta><CR>
+ok<CR>< LF ><CR>< LF >
Parameters:
sta.: module’s transmit power, ranging from 0 to 100. Default is 100.
4.3.4.54. AT+REGCLOUD
Function: Query/Set USR Cloud ID and password.
Format:
Query : AT+REGCLOUD<CR>
+ok=<name,password><CR><LF><CR><LF>
Setting: AT+REGCLOUD=<name,password><CR>
+ok<CR>< LF ><CR>< LF >
Parameters:
name
:
device ID, 20 digits.
password: password, up to 8 digits.
For example: AT+REGCLOUD=00004219000000000600,123456
4.3.4.55. AT+REGUSR
Function: Query/Set user custom registration package content
Format:
Query : AT+REGUSR<CR>
+ok=<usr><CR><LF><CR><LF>
Setting: AT+REGUSR=<usr><CR>
+ok<CR>< LF ><CR>< LF >
Parameters:
Usr: Length is limited to 40 characters, HEX format.
For example: set the registration package content to: www.usr.cn, “77 77 77 2E 75 73 72 2E 63 6E” in HEX