Table 40: Torque reference parameters
Index Parameter Min Max Unit Default ID Description
P3.3.2.1
Torque Reference
Selection
0 26 0 * 641
0 = Not used
1 = Keypad
2 = Joystick
3 = AI1
4 = AI2
5 = AI3
6 = AI4
7 = AI5
8 = AI6
9 = ProcessDataIn 1
10 = ProcessDataIn 2
11 = ProcessDataIn 3
12 = ProcessDataIn 4
13 = ProcessDataIn 5
14 = ProcessDataIn 6
15 = ProcessDataIn 7
16 = ProcessDataIn 8
17 = Block Out.1
18 = Block Out.2
19 = Block Out.3
20 = Block Out.4
21 = Block Out.5
22 = Block Out.6
23 = Block Out.7
24 = Block Out.8
25 = Block Out.9
26 = Block Out.10
P3.3.2.2
Torque Minimum
Reference
-300.0 300.0 % 0.0 643
P3.3.2.3
Torque Maximum
Reference
-300.0 300.0 % 100.0 642
P3.3.2.4
Torque Reference
Filter Time
0.00 300.00 s 0.00 1244
P3.3.2.5
Torque Reference
Dead Zone
0.0 300.0 % 0.0 1246
P3.3.2.6
Keypad Torque Ref-
erence
0.0 P3.3.2.3 % 0.0 1439
P3.3.2.7
Torque Control Fre-
quency Limit
0 1 0 1278
0 = Pos/Neg frequency
limits
1 = frequency refer-
ence
M3.3.2.8
Torque Control Open
Loop
This menu includes 3 parameters. See table Table 41.
PARAMETERS MENU VACON · 109