vacon • 70 Commissioning
Local contacts: https://www.danfoss.com/en/contact-us/contacts-list/
To use emulation mode, you need OPTEA with firmware version V002 or later and VACON
®
NXP drive
with V197 firmware or later.
6.5.1 Modbus in emulation mode
NX Mode:
"Currently this mode has no effect on Modbus functionality
OPTCx Mode:
Modbus supports all the same coils as OPTCI board does
Measurement table indexes are supported
6.5.2 EtherNet/IP in emulation mode
NX Mode:
PLC must use OPTCQ EDS.
AC/DC Drive Object: Parameter "Drive" mode will always return the actual drive mode.
In "normal" mode "process drive" mode value is returned when the instance number is 25.
Drive identifier text will be "OPTCQ" instead of being based on the drive where the option
board is installed (for example: "VACON
®
100 INDUSTRIAL").
Product code will be "2" instead of being based on the drive where the option board is
installed.
Revision number (major, minor) will be OPTCQ's 3.5.
Connection instance will be OPTCQ's "1" instead of "103" which is used by OPTEA/OPTE9
and VACON
®
100 family AC drive.
Motor Data Object: "Rated Current" attribute will return the value in units of 10 milliamperes
(1.9A => 190). In Normal mode, the value unit is 100 milliamperes (1.9A => 19). The same
conversion is expected when setting the attribute value.
The Motor Data Object: "Rated Frequency" attribute will return value with two decimals
(50.00Hz => 5000). In normal mode, the value has no decimals (50.00Hz => 50Hz). The same
conversion is expected when setting the attribute value.
ControlFromNet bit is set to 1 when NetControl is set to 1. In normal mode, it is set only if
Control Place-parameter is set to fieldbus.
ReferenceFromNet bit is set to 1 when NetworkReference is set to 1. In normal mode, it is
set only if Reference Place-parameter is set to fieldbus.
OPTCx Mode:
All same changes as in NX Mode.
VACON
®
100 Mode:
PLC must use Vacon 100 EDS.
Drive identifier text will be "VACON
®
100" instead of being based on the drive where the
option board is installed (for example: "VACON
®
100 INDUSTRIAL").
Product code will be "100" instead of being based on the drive where the option board is
installed.
Revision number (major, minor) will always be 2.1.