APPENDIX 1 - VACON® IO DATA DESCRIPTION vacon • 207
Local contacts: https://www.danfoss.com/en/contact-us/contacts-list/
11
11.2 Control Word bit support in VACON
®
AC drives
The following table describes the control word bit support in different drives. Notice that this table
is valid only for VACON
®
standard applications. Always check the application-specific manual.
Table 208. FBFixedControlWord bit support in different VACON
®
AC drives
x) Supports standard function
o) FBDIN-function instead of standard function
Bit Function
VACON
®
100
family
VACON
®
NXP
VACON
®
20
VACON
®
20 X/CP
0Start/Stop xxxx
1 Direction x x x x
2Fault reset xxxx
3 Stop mode 1 x 0 x
4 Stop mode 2 x 0 x
5 Quick ramp time x 0 x x
6 Freeze setpoint x 0 x
7 Setpoint to zero x 0 x
8
Request Fieldbus
Control
xx x
9
Request Fieldbus
Reference
xx x
10 Jogging 1 x
11 Jogging 2 x
12 Quick stop x x
13-14 Reserved
15 Master connection x