Table 12 Temperature Specifications (and Operating Pressure
Ranges)
Property Description / Value
HMT311 -40 ... +60 °C (-40 ... +140 °F)
HMT313 80 °C -40 ... +80 °C (-40 ... +176 °F)
HMT313 120 °C -40 ... +120 °C (-40 ... +248 °F)
HMT314 -70 ... +180 °C (-94 ... +356 °F),
0 ... 10 MPa (0 ... 100 bar)
HMT315 (vapor tight) -70 ... +180 °C (-94 ... +356 °F)
HMT317 (vapor tight) -70 ... +180 °C (-94 ... +356 °F)
HMT318 -70 ... +180 °C (-94 ... +356 °F),
0 ... 4 MPa (0 ... 40 bar)
Accuracy at +20 °C (+68 °F) ±0.2 °C
Accuracy over temperature range See Figure 18 below.
Typical temperature dependence of
electronics
±0.05°C/°C (±0.005°F/°F)
Temperature sensor Pt 100 RTD 1/3 Class B IEC 751