Damping: Damping the fluctuation of the output signal, 1–60 sec. Define at least the
min. value required to damp harmful fluctuations.
Alarm current: Analog output current to indicate device failure. Possible values are 3.7
mA, 22.5 mA, HOLD (analog output is frozen when alarm goes on) and NONE (no
alarm signal at all). Default, 3.7 mA.
9.3 Output signal 2
Selected variable: Ash consistency.
Other settings same as in Output signal 1.
9.4
User settings
Tag: Device tag is a text describing the installa-
tion position of the device. Max. 8 characters,
letters/ numbers.
Temp unit: Temperature unit, degrees in Cel-
sius = °C / Fahrenheit = °F. Default, C.
Configuration | 30 (48)
K20798 V1.1 EN - 1 - 12/2019