Series 65 MAINTENANCE
963283EA Edition 2019-05-03 113/
129
29. Install controller
Tighten the controller screws with
3 Nm.
Connect cables at controller
Connect compressed air at
actuator
Allen Wrench
4mm
30. Turn on power of controller.
Valve moves to close
position.
31. Open valve and install sealing
ring and pendulum plate in
reverse order as they had been
disassembled
(steps 11 to 2).
open end wrench
13mm
32. Clean the valve sealing surface
Lint-and dust-free
towel a little
soaked with
isopropyl alcohol
33. Clean the valve bonnet o-ring
Lint-and dust-free
towel
34. Mount valve bonnet.
Tightening torques for bonnet
screws, see in table to the right.
Max. torque 6 Nm
Allen wrench
5mm
35. To leave the maintenance mode
press “Restart” button or power
cycle the controller.
36. Set the valve to remote mode
CPA & Service
cable
(PC to valve
Service
connector)

Table of Contents