Changing of lifting cylinder(s)Changing of lifting cylinder(s)
Changing of lifting cylinder(s)
Changing of lifting cylinder(s)
Changing of lifting cylinder(s)
TIP! Measure the settings of the
spring on both sides of the
machine.
Loosen the springs and
remove the spindles on both
sides of the machine. Remove
cotter bolts on both sides of
the machine.
NB! Protect the top of the
machine with a piece of
cardboard or something similar.
Remove cotter bolts on both
sides of the machine.
Replace the hydraulic
cylinders.
Note; cylinders are not the same
in diameter;
* RH side 55 mm.(2
11
64
”)
* LH side 65 mm. (2
9
16
”)
Fit the cotter bolts on both
sides of the machine.
Fit the spindles on the springs
in both sides of the machine.
Fit / connect all hydraulic
hoses on the hydraulic
cylinders.
Changing of lifting cylinder(s)
Changing of lifting cylinder(s)
Changing of lifting cylinder(s)
Lower the cutting unit of the
machine down on the ground.
Make sure that the
hydraulic system of the
machine is released of all
pressure
Remove all hydraulic hoses
from the hydraulic cylinders.
Protect the open ends of the
hoses against dirt.
4.3.2 Replacement lifting cylinders