40 - ENGLISH
Synchronising an already-initialised reader
6.8.12
Insert a MASTER smart card already pro-
grammed by the reader/programmer.
6.8.13
The LED turns off to indicate that the
MASTER smart card has been recog-
nised.
If the smart card is not recognised, the LED turns
red and remains illuminated until the card is re-
moved.
6.8.11
Press the front button within 9 seconds.
The LED turns green.
Warning!
If the button is not pressed within 9 seconds,
the LED turns green and the system switches to
the “Initialise reader and program SLAVE smart
card” procedure. To exit the procedure, place
dip-switch 1 in the OFF position.
Repeat the procedure from step 6.8.10.
6.8.10
Place dip-switch 1 on the reader being
synchronised in the ON position.
The LED lights up yellow.
The device waits for the MASTER smart card for
about 2 minutes, after which the LED turns yel-
low and no further commands are accepted. To
resume normal operation place dip-switch 1 in
the OFF position.
1 2 3
4 5 6
7 8
ON
yellow
green
MASTER
card
MASTER
card
2 minutes
MASTER
card
MASTER
card
green
yellow
off