D-307083 PowerMaster-360R Installer's Guide 13
Deleting a Z-Wave device
To delete an enrolled device, press and hold the (-) button (U in Figure 3.1) for 2 seconds. The red LED (T in Figure 3.1)
blinks quickly, a success beep is emitted, and the LED turns off.
Notes:
To cancel the deletion, press and hold the (+) or (-) buttons for 2 seconds. The LED stops blinking.
If the deletion is not successful, the red LED lights for 3 seconds and a failure beep is emitted.
To return the panel to normal operation, long press on the (-) button.
3.9 Panel reset
To reset the panel, use a blunt instrument to press the reset button (K in Figure 3.1), or, alternatively, exit the Installer
Mode. The Orange LED (T in Figure 3.1) lights constantly until panel initialization is complete. When the PowerLink is
reset, the Orange LED (T) turns off.
3.10 Factory default restore
To restore system parameters to the factory default parameters, complete the following steps:
Note: The panel must be disarmed before performing the reset.
1. Press the Back to Factory button (J in Figure 3.1) for 30 seconds.
Note: During Back to Factory, the red LED (T in Figure 3.1) blinks.
2. If Back to Factory is successful the green LED blinks 3 time, a success beep sounds, and the panel immediately
initiates software reset.
Note: If the Back to Factory procedure fails, the red LED lights constantly for 3 seconds and a failure beep sounds.