APPENDIX F. Event Codes
78 D-307083 PowerMaster-360R Installer's Guide
System battery disconnect
System Battery Trouble / Disconnection
F3. Understanding the Scancom Reporting Protocol Data Format
The SCANCOM data format consists
of 13 decimal digits divided into 4
groups, from left to right, as shown on
the right.
Each channel is associated with a
specific event as follows:
1
st
C: Fire
2
nd
C: Personal attack
3
rd
C: Intruder
4
th
C: Open/close
5
th
C: Alarm cancel
6
th
C: Emergency
7
th
C: Second alarm
8
th
C: Trouble messages
System Status:
no trouble, test,
low battery
The digit in this position
conveys the status of
channel 1
The digit in this position
conveys the status of
channel 8
F4. SIA over IP - Offset for Device User
System tamper would report as 000
Zone 5 would report as 005
Keyfob/User number 101 would report
601
Pendant number 1 would report 651
Keypad number 8 would report 708
Siren number 9 would report 809
Repeater number 4 would report 834
Device number 2 would report 852
Troubles for:
GSM
BBA
Plink
Guard
GSM module network fail 876
BBA bus trouble 877