4. Programming
D-307083 PowerMaster-360R Installer's Guide 17
4.2.2 Selecting options
Selecting an option from a menu
Example: To Select an Option from the COMMUNICATION menu:
[1]
Enter the Installer Mode menu and select the 04.COMMUNICATION option (see section 4.2).
[2]
Select the sub-menu option you need, for example: 3: C.S. REPORTING.
[3]
Select the parameter you wish to configure for example: 11:RCVR 1 ACCOUNT
[4]
To continue, go to the section of the selected sub-menu option, for example section 4.6.3 for the
3:C.S.REPORTING menu. Then look for the sub-menu you wish to configure for example, 11:RCVR 1
ACCOUNT. After configuring the selected parameter the display returns to step 3.
To Change the Configuration of the Selected Option:
When entering the selected option, the display shows the default (or the previously selected) setting marked with
.
To change the configuration, scroll the Options menu and select the setting you wish and press to
confirm. When done, the display reverts to Step 3.
4.2.3 Exiting the installer mode
To exit the Installer Mode, proceed as follows:
Step 1
Step 2
Step 3
[1]
[2]
[3]
Any screen
or
<OK> TO EXIT
READY 12:00
Exiting the Installer Mode
[1]
To exit INSTALLER MODE, move up the menu by pressing the button repeatedly until the display
reads <OK> TO EXIT or press the button once which brings you immediately to the exit screen
<OK> TO EXIT.
[2]
When the display reads <OK> TO EXIT, press .
[3]
The system exits the INSTALLER MODE menu and returns to the normal disarm state while showing the
READY display.
4.3 Setting installer codes
The PowerMaster-360R system provides two installer permission levels with separate installer codes, as follows:
Master Installer: The Master Installer is authorized to access all Installer Mode menu and sub-menu options. The
default code is: 9999 (*).
Installer: The Installer is authorized to access most but not all Installer Mode menu and sub-menu options. The
default code is 8888 (*).
Guard Code: Enables an authorized guard to only Arm Away / Disarm the control panel. The default code is 0000 (*).
The following actions require you to enter the Master Installer code:
Changing the Master Installer code.
Defining specific communication parameters – see 3:C.S REPORTING in section 4.6.2 and 4.6.3.
Resetting the PowerMaster-360R parameters to the default parameters – see 09:FACTORY DEFLT in section
4.11.
Note: Not every system includes a Master Installer code feature. In such systems, the Installer can access all Installer
Mode menu and sub-menu options identical to the Master Installer.
(*) You are expected to use the default codes only once for gaining initial access, and replace it with a secret
code known only to yourself.