APPENDIX C. Specifications
72 D-307083 PowerMaster-360R Installer's Guide
C3. Electrical
Input: AC 100-240V, 50/60 Hz, 0.4A
Output: 5.1V DC 1.96A
~ 200 mA standby, 1500 mA peak at full load.
3.7 V, 3000 mAh LIPO, maximum charging voltage is 4.2 V.
Siren Sound Acoustic output
4 minutes by default; 20 minutes maximum value
Peak current consumption in
alarm sounding state
Peak current consumption in
non-alarm sounding state
Average current consumption
and peak current consumption
PG2 - 40/120 mA
Z-WAVE - 30/40 mA
WiFi - 400 mA
Cellular - 25 mA/2A
IP, Ethernet 10/100 (primary mode), and GPRS (secondary mode)
Monitoring Station Report
2 via PowerManage on IP and/or GPRS and/or Wi-Fi
Local Management Protocol to
Windows PC and Android Mobile
2 Monitoring Stations, 4 private SMS telephones via the server and 4 emails
Operating Temperature Range
32°F to 120°F (0°C to 50°C)
Storage Temperature Range
5°F to 140°F (-15°C to 60°C)
93% relative humidity, @ 30°C (86°F)
158x114.5x36.5 mm (6.22x4.5x1.43 in.)