4. Programming
34 D-307083 PowerMaster-360R Installer's Guide
4.5.8 Configuring miscellaneous features
The following table provides you with a detailed description of each option and its configuration settings. To select an
option and change its configurationrefer to section 4.5.1.
Option
Configuration instructions
80:3
rd
PARTY H.A
Determines if a third party home automation interface is connected or not.
Options: disable (default) or enable
91:USER PERMIT
User Permission enables you to determine whether access to the INSTALLER MODE requires
the user's permission or not. If you select enabled, the installer will be able to access the system
only through the user menu after the user code has been entered (see section 4.2).
Options: disable (default) or enable (default in UK).
Note: To comply with EN requirements, Enable must be selected.
93:SOAK PERIOD
Define the period of time for the Soak Test.
Options: Disable (default), 7 days, 14 days or 21 days.
Notes:
1. If set to one of the above pre-defined period of times, to be operational Soak Test mode
must also be set to Enable Test from the 02:ZONES/DEVICES menu (see Section 4.4.6).
2. If a change is made to the period of time of the Soak Test while the zone is currently being
tested, this will restart the Soak Test.
3. The start of the Soak Test period is defined in the factory from 9 AM (09:00).