4. Programming
D-307083 PowerMaster-360R Installer's Guide 45
5. When the configuration is complete, from the ACCESS-Point menu, select STOP A.Point to close the
access-point.
Note: By default the total time for access-point activity is one hour. Five minutes before the access-point is
deactivated, a message is sent to the installer. You can extend the time by activating the access-point again
from the menu.
From the installer mode menu, select the following options:
04:COMMUNICATION
8:WiFi
ACCESS-POINT
Configuration instructions
From the WiFi ACCESS-POINT menu you can enable, activate, and deactivate an access-
point.
8:WiFi > ACCESS-
POINT > A.POINT MODE
To enable WiFi access, from the ACCESS-POINT menu select A.POINT MODE.
Select enable to activate or disable to deactivate wireless activity.
Options: Disable (default); Enable.
8:WiFi > ACCESS-
POINT > START
A.POINT
To activate an access-point channel for wireless access, from the ACCESS-POINT menu
select START A.POINT.
The panel shows the status when you open the access-point channel.
For example, Please Wait, OK or FAIL.
8:WiFi > ACCESS-
POINT > STOP A.POINT
To close the access-point channel, from the ACCESS-POINT menu, select STOP
A.POINT.
The panel shows the status when you close the access-point channel.
4.7 PGM Output
4.7.1 General Guidance
The "05:OUTPUTS" menu enables you to select events/conditions under which the PGM (programmable) output will
function.
To configure a PGM output located on the WL-IOG general Inputs / Outputs wireless transceiver device, use the
following menu path:
05:OUTPUS
PGM OUTPUTS
PGM ON CONTACTS
MENU you wish
Enter "PGM ON CONTACTS", select the zone or device and the PGM PIN number you wish to configure, and then
refer to the table in section 5.7.3 for PGM configuration instructions.
Note: PGM is not to be enabled in UL Listed Products.
4.7.2 PGM Output Configuration
Define which factors, including any combination of factors, will determine the PGM output.
Configuration Instructions
PGM: BY ARM AWAY
PGM: BY ARM HOME
PGM: BY DISARM
Determine to activate the PGM output upon arming Away / Home / Disarm.
Options: disable (default); turn ON; turn OFF; activate PULSE.
Determine to activate the PGM output upon registration of an alarm in the memory. The
output will restore to normal upon memory clearing.
Options: disable (default); turn ON; turn OFF; activate PULSE.
Note: In Soak Test
1
mode and when BY MEMORY is enabled, the PGM will not be
activated.
Soak Test is not applicable for UL installations