4. Programming
16 D-307083 PowerMaster-360R Installer's Guide
4.1.2 Feedback sounds
The panel or PC provides the following audible indicators when configuring the panel:
Sound
Definition
Single beep indicates that a key is pressed.
Double beep indicates a return to the normal operating mode after a timeout.
Three beeps indicate an abnormal condition in the system due to a fault.
Success Tune (- - - –––), indicates the successful completion of an operation.
Failure Tune (–––––), indicates an incorrect option or the value that is not accepted.
4.2 Entering installer mode and selecting a menu option
All installer mode options are accessed from the installer mode menu option.
To enter and select an option from the Installer Mode menu, complete the following steps:
Step 1
Step 2
Step 3
Step 4
Select Installer Mode
Option
[1]
Enter
Installer Code
[2]
Select Installer Mode menu option
[3]
See
See
READY 00:00
01:INSTALL CODES
4.3
08:USER SETTINGS
4.10
Go to
the
indicated
section
of the
selected
option
02:ZONES/DEVICES
4.4
09:FACTORY DEFLT
4.11
INSTALLER MODE
ENTER CODE:
03:CONTROL PANEL
4.5
10:SERIAL NUMBER
4.12
If the Installer Mode
is not shown, refer to
section 4.2.1
04:COMMUNICATION
4.6
12:PARTITIONING
4.13
06:CUSTOM NAMES
4.8
13:OPERATION MOD
4.14
07:DIAGNOSTICS
4.9
<OK> TO EXIT
- Entering the Installer Mode menu
[1]
You can access the Installer Mode only when the system is disarmed. The process described refers to the
case where a User permit is not required. If a User permit is required, select the User Settings option and
ask the Master User to enter his code and then scroll to the User Settings menu and select the Installer
Mode option (last option in the menu). Continue to Step 2.
[2]
If you have not already changed your Installer code number, use the default settings: 8888 for installer & 9999
for master installer.
If you enter an invalid installer code 3 - 5 times, the keypad is automatically disabled for a pre-defined period
of time and the message WRONG PASSWORD is displayed.
[3]
You have now entered the Installer Mode menu. Scroll and select the menu you require and see the relevant
section in the guide, the section is indicated on the right side of each option.
4.2.1 Entering the installer mode when User Permit is enabled
In certain countries the regulations may require that the user grants permission to make changes to the panel
configuration. To comply with these regulations, the Installer Mode option can be accesses only from the User
Settings menu. The Master user must first enter the User Settings menu and scroll until the Installer Mode option is
shown and then the installer can continue as shown in the above table (see also [1] in Step 1 above).
To configure the panel to comply with user permission requirements - see option #91 User Permit in section 4.5.8.