4. Programming
D-307083 PowerMaster-360R Installer's Guide 25
4.4.6 Configuring soak test mode
This option enables you to enter device zones into Soak Test mode.
To Enable the Soak Test proceed as follows:
Step 1
Step 2
Step 3
Step 4
Step 5
Select ADD TO SOAK
TEST Option
[1]
Select the respective
device Group
[2]
Select device zone
number
[3]
Select to enable or
disable the Soak Test
[4]
[5]
02:ZONES/DEVICES
CONTACT
SENSORS
Z09:Motion Sens
ID No. 120-2468
ADD TO SOAK TEST
MOTION SENSORS
Disable test
Enable test
See
[5]
to
Step 3
Enabling Soak Test mode
[1]
Enter the Installer Mode menu, select the 02.ZONES/DEVICES option (see section 4.2) and then select the ADD
TO SOAK TEST option.
[2]
Select the respective Group of the device you wish to add the Soak Test. For example, MOTION SENSORS.
[3]
Scroll to select the specific device zone number.
[4]
Select between Disable test (default) or Enable test.
[5]
If set to Enable Test you must set the duration of the Soak Test before the Soak Test will start (see section
4.5.8). You can stop the test for the relevant zone by changing the setting to Disable test at any time during
the testing period. All Soak test zones will be reset to start a new test upon occurrence of one of the following:
1) Power up of the system; 2) Setup of Factory Default; 3) Change in system Soak Time.