4. Programming
32 D-307083 PowerMaster-360R Installer's Guide
Option
Configuration instructions
51:PIEZO BEEPS with
partition enabled
Define whether or not the panel exit or entry warning beeps sound during exit and entry delays.
An additional option is to mute the warning beeps only when the system is armed “HOME”.
The control panel’s display is: Def:P1 P2 P3
Press the buttons , , or to select the corresponding partitions. Pressing
each button repeatedly toggles between the following options.
Options: (enable beeps), H (OFF when home), h (OFF exit home) and
(disable beeps).
Notes:
1. When exit beeps are OFF, the happy (success) melody still sounds toward the end of an
exit delay.
2. The volume level of the exit or entry beeps can be modified by pressing the button
on the keypad to increase the volume, or by pressing the button to decrease the
volume.
52:TROUBLE BEEPS
Under trouble conditions, the panel sounder emits a series of 3 short reminder beeps once
per minute. Define whether to enable or disable this reminder beeping or just disable it at
night. The “night” hours are predefined factory settings but are usually from 8 PM (20:00) until
7:00 AM.
Options: ON (default in USA only); OFF at night (default) and OFF.
53:MEMORY
PROMPT
Define whether or not the user will receive Memory indication on the Virtual or Touch Keypad
that an alarm has been activated. By pressing the button in standby mode, you can
view details of the alarm memory.
Options: ON (default) and OFF.
54:LOW-BAT ACK
You can activate or deactivate the Low Battery Acknowledge requirement from the user whose
keyfob's battery is low. For further information, see PowerMaster-360R User's Guide Chapter 6.
Options: OFF (default) – acknowledge not needed; ON – acknowledge required.
55:BACK LIGHT
Define whether the panel's back lighting remains on at all times or turns on only when a key is
pressed and turns off within 10 seconds if no further keystrokes are sensed.
Options: always ON and OFF after 10 sec (default).
56:SCREEN SAVER
with partition disabled
The Screen Saver option (when activated) replaces the status display on the Virtual or
Touch Keypad with PowerMaster-360R display if no key is pressed during more than 30
seconds.
You can activate the Screen Saver and determine whether the status display will resume
following any key press (refresh by Key) or by entering a code (refresh by Code). If refresh
by Key is selected, the first pressing of any key (except Fire and Emergency) will produce the
status display and the second press will perform the key function. For further information, see
the User's Guide, Chapter 1, Screen Saver Mode.
Options: OFF (default); refresh by Code and refresh by Key.
Notes:
1. To comply with EN requirements, refresh by code must be selected.
2. For Fire and Emergency keys, the first key press will produce the status display and will also
perform the Fire/Emergency function.
56:SCREEN SAVER
With Partition
enabled
Certain regulations require that the system status display will not be exposed to unauthorized
persons. The Screen Saver option (when activated) replaces the system status indication on
the Virtual or Touch Keypad with idle text if no key is pressed during more than 30 seconds.
You can activate the Screen Saver option and determine whether the status display will
resume following any key press (Text - by Key) or by entering a code (Text - by Code). If
Text by Key is selected, the first pressing of any key (except Fire and Emergency) will
produce the status display and the second press will perform the key function. Regarding the
Fire and Emergency keys, the first key press will produce the status display and will also