4. Programming
D-307083 PowerMaster-360R Installer's Guide 39
Option
Configuration instructions
12:RCVR2 ACCOUNT
identify your specific alarm system to the 1
st
Monitoring Station (designated as RCVR1 or
RCV1) and a 2
nd
Account (subscriber) number (12:RCVR 2 ACCOUNT) that will identify the
system to the 2
nd
Monitoring Station (designated as RCVR2 or RCV2). Each of the Account
numbers consists of 6 hexadecimal digits.
Master Installer only
To enter Hexadecimal digits, use the following table:
Entering Hexadecimal Digits
Digit
0…..9
A
B
C
D
E
F
Keying
0…..9
[#]
[0]
[#]
[1]
[#]
[2]
[#]
[3]
[#]
[4]
[#]
[5]
21:IP RCVR 1
22:IP RCVR 2
Master Installer only
The PowerMaster-360R can be programmed to report event messages defined in the Report
Events option (option 01) to two IP Receivers (PowerManage servers). You can use a maximum
of two IP receivers reporting through a GPRS (IP) channel or broadband IP channel using SIA IP
format.
Enter the IP addresses (000.000.000.000) of receiver one (21:IP RCVR 1) and the IP address of
receiver two (22:IP RCVR 2).
Note: You must enter the IP address of the receiver, even if you enter the Domain Name
System (DNS) server name where the receiver is installed. See option 28:RCVR 1 DNS and
29:RCVR 2 DNS for details on how to enter the DNS name.
26:SMS RCVR 1
27:SMS RCVR 2
Master Installer only
If equipped with GSM module, the PowerMaster-360R can be programmed to report the event
messages defined in Report Events option (option 01) to two SMS Receivers via the GSM
SMS channel using a special SMS text format. For further details concerning the SMS text
format please contact Visonic.
Enter the two telephone numbers (including area code – maximum 16 digits).of the SMS
Receiver 1 located at the 1
st
Monitoring Station (26:SMS RCVR 1) and SMS Receiver 2
located at the 2
nd
Monitoring Station (27:SMS RCVR 2).
Note: To enter the international prefix (
) at the 1
st
digit – key-in [#]
[1].
28:RCVR 1 DNS
29:RCVR 2 DNS
Master Installer only
Specifies the DNS name of the servers where the IP receivers are installed.
Enter the DNS name of the servers where receiver 1 and receiver 2 are installed, the name
can contain a maximum of 32 characters. The DNS name one (28:RCVR 1 DNS) must be
resolved to IP receiver one (21:IP RCVR1) and the DNS name two (29:RCVR 2 DNS) must
be resolved to IP receiver two (22:IP RCVR2).
Note: If you enter the DNS name you must also enter the corresponding IP receiver address.
See option 21:IP RCVR 1 and 22:IP RCVR 2 for details on how to enter the IP receiver’s address.
47:GSM RETRIES
Define the number of times the system will retry to report to the Monitoring Station in case of
failure to report via the cellular connection - GPRS (IP) and SMS.
Options: 2 attempts; 4 attempts (default); 8 attempts; 12 attempts and 16 attempts.
48:BB IP RETRIES
Define the number of times the system will retry to report to the Monitoring Station in case of
failure to report via the Broadband Module connection.
Options: 2 attempts; 4 attempts (default); 8 attempts; 12 attempts and 16 attempts.
51: AUTO-TST LOOP
To verify a proper communication channel, the PowerMaster-360R can be configured to send a
test event to the Monitoring Station periodically. You can set the interval between the
consecutive test events or disable the automatic sending of this event entirely. If the interval is
set for every one day or more then the exact hour of reporting can be selected with option 52.
Options: test OFF (default); every 1/2/5/7/14/30 day(s); and every 5 hours.
52:AUTO TST TIME
Enter the exact time (auto test time) during the day at which the Auto Test message (if
enabled in option 51) will be sent to the Monitoring Station.